Sign in →

Test Code ALBSF Albumin, Spinal Fluid


Ordering Guidance


The SFIG / Cerebrospinal Fluid IgG Index Profile, Serum and Spinal Fluid, in conjunction with OLIG / Oligoclonal Banding, Serum and Spinal Fluid is the recommended test for evaluation of multiple sclerosis.



Specimen Required


Specimen Type: Spinal fluid

Container/Tube: Sterile vial

Specimen Volume: 1 mL

Collection Instructions: Label specimen as spinal fluid.


Useful For

Assessment of blood-brain barrier permeability

Method Name

Nephelometry

Reporting Name

Albumin, CSF

Specimen Type

CSF

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 28 days
  Frozen  28 days
  Ambient  14 days

Reject Due To

Gross hemolysis OK

Clinical Information

Elevated albumin concentration in spinal fluid may serve as an indicator of the permeability status of the blood-brain barrier. Comparison to an ALB / Albumin, Serum concentration is recommended.

Reference Values

0.0-27.0 mg/dL

Interpretation

Elevated albumin concentrations may be observed in patients with a compromised blood-brain barrier.

Cautions

Cerebrospinal fluid albumin has limited utility as a standalone test.

Method Description

The cerebrospinal fluid albumin is determined by immunonephelometry on a Siemens Nephelometer II. In this assay, the light scattered onto the antigen-antibody complexes is measured. The intensity of the measured scattered light is proportional to the amount of antigen-antibody complexes in the sample under certain conditions. If the antibody volume is kept constant, the signal behaves proportionally to the antigen volume. A reference curve is generated by a standard with a known antigen content on which the scattered light signals of the samples can be evaluated and calculated as an antigen concentration. Antigen-antibody complexes are formed when a sample containing antigen and the corresponding antiserum are put into a cuvette. A light beam is generated with a light emitting diode, which is transmitted through the cuvette. The light is scattered onto the immuno-complexes that are present. Antigen and antibody are mixed in the initial measurement, but no complex is yet formed. An antigen-antibody complex is formed in the final measurement. The result is calculated by subtracting the value of the final measurement from the initial measurement. The distribution of intensity of the scattered light depends on the ratio of the particle size of the antigen-antibody complexes to the radiated wavelength.(Instruction manual: Siemens Nephelometer II. Siemens, Inc; Version 2.3, 2008; Addendum to the Instruction Manual 2.3, 08/2017)

Day(s) Performed

Monday through Friday

Report Available

1 to 3 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

82042

LOINC Code Information

Test ID Test Order Name Order LOINC Value
ALBSF Albumin, CSF 1746-7

 

Result ID Test Result Name Result LOINC Value
ALBSF Albumin, CSF 1746-7