Sign in →

Test Code CSMTU Controlled Substance Monitoring Targeted Profile, 17 Drug Classes, Mass Spectrometry, Random, Urine


Ordering Guidance


This test does not screen for drug classes other than those listed in Reference Values.



Specimen Required


Supplies: Urine Tubes, 10 mL (T068)

Collection Container/Tube: Plastic urine container

Submission Container/Tube: Plastic, 10 mL tube

Specimen Volume: 5 mL

Collection Instructions:

1. Collect a random urine specimen.

2. Submit 5 mL in 1 plastic bottle.

3. No preservative

Additional Information:

1. No specimen substitutions.

2. Submitting less than 5 mL may compromise the ability to perform all necessary testing.

3. STAT requests are not accepted for this test.


Useful For

Detecting drug use involving stimulants, benzodiazepines, and opioids

 

This test is not intended for use in employment-related testing.

Profile Information

Test ID Reporting Name Available Separately Always Performed
LPCM List Patient's Current Medications No Yes
ADULT Adulterants Survey, U Yes Yes
TOPSU Targeted Opioid Screen, U Yes, (order TOSU) Yes
TABSU Targeted Benzodiazepine Screen, U Yes, (order TBSU) Yes
TSTIM Targeted Stimulant Screen, U Yes, (order TSPU) Yes

Testing Algorithm

Testing begins with an adulterant survey. If the sample is found to be adulterated, testing will end, and the remaining tests will be canceled.

 

If the specimen is normal or only diluted, testing will proceed.

Method Name

ADULT: Spectrophotometry

TOPSU, TABSU, TSTIM: Liquid Chromatography Tandem Mass Spectrometry, High-Resolution Accurate Mass (LC-MS/MS HRAM)

Reporting Name

CSM Targeted Drug Profile,17,HRMS,U

Specimen Type

Urine

Specimen Minimum Volume

2 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 14 days
  Frozen  14 days

Reject Due To

  All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Clinical Information

The targeted opioid, benzodiazepine, and stimulant screen portions are performed by liquid chromatography tandem mass spectrometry, high-resolution accurate mass (LC-MS/MS HRAM) and are completed for all opioids, benzodiazepines, and stimulants.

 

Opioids are a large class of medications commonly used to relieve acute and chronic pain or help manage opioid abuse and dependence. Medications that fall into this class include buprenorphine, codeine, fentanyl, hydrocodone, hydromorphone, methadone, morphine, oxycodone, oxymorphone, tapentadol, tramadol, and others. Opioids work by binding to the opioid receptors that are found in the brain, spinal cord, gastrointestinal tract, and other organs. Common side effects of opioids include drowsiness, confusion, nausea, constipation, and, in severe cases, respiratory depression. These are dose dependant and vary with tolerance. These medications can also produce physical and psychological dependence and have a high risk for abuse and diversion, which is one of the main reasons many professional practice guidelines recommend compliance testing in patients prescribed these medications.

 

Opioids are readily absorbed from the gastrointestinal tract, nasal mucosa, lungs, and after subcutaneous or intermuscular injection. Opioids are primarily excreted from the kidney in both free and conjugated forms. This assay does not hydrolyze the urine sample and looks for both parent drugs and metabolites (including glucuronide forms). The detection window for most opioids in urine is approximately 1 to 3 days with longer detection times for some compounds (eg, methadone).

 

Benzodiazepines represent a large family of medications used to treat a wide range of disorders from anxiety to seizures and are also used in pain management. With a high risk for abuse and diversion, professional practice guidelines recommend compliance monitoring for these medications using urine drug tests. However, traditional benzodiazepine immunoassays suffer from a lack of cross-reactivity with all the benzodiazepines, so many compliant patients taking either clonazepam (Klonopin) or lorazepam (Ativan) may screen negative by immunoassay but are positive when confirmatory testing is done. The new targeted benzodiazepine screening test provides a more sensitive and specific test to check for compliance to all the commonly prescribed benzodiazepines and looks for both parent drug and metabolites in the urine.

 

Stimulants are sympathomimetic amines that stimulate the central nervous system activity and, in part, suppress the appetite. Amphetamine and methamphetamine are also prescription drugs used in the treatment of narcolepsy and attention-deficit disorder/attention-deficit hyperactivity disorder (ADHD). Methylphenidate is another stimulant used to treat ADHD. Phentermine is indicated for the management of obesity. All other amphetamines (eg, methylenedioxymethamphetamine: MDMA) are Drug Enforcement Administration-scheduled Class I compounds. Due to their stimulant effects, the drugs are commonly sold illicitly and abused. Physiological symptoms associated with very high amounts of ingested amphetamine or methamphetamine include elevated blood pressure, dilated pupils, hyperthermia, convulsions, and acute amphetamine psychosis.

 

This test is intended to be used in a setting where the test results can be used to make a definitive diagnosis.

Reference Values

ADULTERANT SURVEY:

Cutoff concentrations

Oxidants: 200 mg/L

Nitrites: 500 mg/L

 

TARGETED OPIOID SCREEN:

Not detected

 

Cutoff concentrations:

Codeine: 25 ng/mL

Codeine-6-beta-glucuronide: 100 ng/mL

Morphine: 25 ng/mL

Morphine-6-beta-glucuronide: 100 ng/mL

6-Monoacetylmorphine: 25 ng/mL

Hydrocodone: 25 ng/mL

Norhydrocodone: 25 ng/mL

Dihydrocodeine: 25 ng/mL

Hydromorphone: 25 ng/mL

Hydromorphone-3-beta-glucuronide: 100 ng/mL

Oxycodone: 25 ng/mL

Noroxycodone: 25 ng/mL

Oxymorphone: 25 ng/mL

Oxymorphone-3-beta-glucuronide: 100 ng/mL

Noroxymorphone: 25 ng/mL

Fentanyl: 2 ng/mL

Norfentanyl: 2 ng/mL

Meperidine: 25 ng/mL

Normeperidine: 25 ng/mL

Naloxone: 25 ng/mL

Naloxone-3-beta-glucuronide: 100 ng/mL

Methadone: 25 ng/mL

2-Ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP): 25 ng/mL

Propoxyphene: 25 ng/mL

Norpropoxyphene: 25 ng/mL

Tramadol: 25 ng/mL

O-desmethyltramadol: 25 ng/mL

Tapentadol: 25 ng/mL

N-desmethyltapentadol: 50 ng/mL

Tapentadol-beta-glucuronide: 100 ng/mL

Buprenorphine: 5 ng/mL

Norbuprenorphine: 5 ng/mL

Norbuprenorphine glucuronide: 20 ng/mL

 

TARGETED BENZODIAZEPINE SCREEN:

Not detected

 

Cutoff concentrations:

Alprazolam: 10 ng/mL

Alpha-hydroxyalprazolam: 10 ng/mL

Alpha-hydroxyalprazolam glucuronide: 50 ng/mL

Chlordiazepoxide: 10 ng/mL

Clobazam: 10 ng/mL

N-desmethylclobazam: 200 ng/mL

Clonazepam: 10 ng/mL

7-Aminoclonazepam: 10 ng/mL

Diazepam: 10 ng/mL

Nordiazepam: 10 ng/mL

Flunitrazepam: 10 ng/mL

7-Aminoflunitrazepam: 10 ng/mL

Flurazepam: 10 ng/mL

2-Hydroxy ethyl flurazepam: 10 ng/mL

Lorazepam: 10 ng/mL

Lorazepam glucuronide: 50 ng/mL

Midazolam: 10 ng/mL

Alpha-hydroxymidazolam: 10 ng/mL

Oxazepam: 10 ng/mL

Oxazepam glucuronide: 50 ng/mL

Prazepam: 10 ng/mL

Temazepam: 10 ng/mL

Temazepam glucuronide: 50 ng/mL

Triazolam: 10 ng/mL

Alpha-hydroxytriazolam: 10 ng/mL

Zolpidem: 10 ng/mL

Zolpidem phenyl-4-carboxylic acid: 10 ng/mL

 

TARGETED STIMULANT SCREEN:

Not detected

 

Cutoff concentrations:

Methamphetamine: 100 ng/mL

Amphetamine: 100 ng/mL

3,4-Methylenedioxymethamphetamine (MDMA): 100 ng/mL

3,4-Methylenedioxy-N-ethylamphetamine (MDEA): 100 ng/mL

3,4-Methylenedioxyamphetamine (MDA): 100 ng/mL

Ephedrine: 100 ng/mL

Pseudoephedrine: 100 ng/mL

Phentermine: 100 ng/mL

Phencyclidine (PCP): 20 ng/mL

Methylphenidate: 20 ng/mL

Ritalinic acid: 100 ng/mL

Interpretation

A positive result derived by this testing indicates that the patient has used one of the drugs detected by these techniques in the recent past.

 

For information about drug testing, including estimated detection times and Result Interpretations, see Controlled Substance Monitoring on MayoClinicLabs.com.

Cautions

No significant cautionary statements

Method Description

Adulterant:

All results are measured using spectrophotometry at wavelengths specified by the reagent manufacturer. The use of a refractometer may also be used in the specific gravity measurement.(Package inserts: Specimen Validity Test Creatinine. Roche Diagnostics; V3.0, 08/2015; Specimen Validity Test Nitrite. Roche Diagnostics; V3.0, 08/2018, Specimen Validity Test Oxidant. Roche Diagnostics; V 3.0, 08/2018; Specimen Validity Test pH Roche Diagnostics; V3.0, 02/2019, Specimen Validity Test Specific Gravity. Roche Diagnostics; V4.0, 08/2022)

 

Targeted Screening Panels for opioids, benzodiazepines, and stimulants:

The urine sample is diluted with internal standard and clinical laboratory reagent water and then analyzed by liquid chromatography tandem mass spectrometry using a high-resolution accurate mass orbitrap detector.(Unpublished Mayo method)

Day(s) Performed

Monday through Saturday

Report Available

3 to 4 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

80347

80364

80326

G0482 (if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CSMTU CSM Targeted Drug Profile,17,HRMS,U 69739-1

 

Result ID Test Result Name Result LOINC Value
LPCM List Patient's Current Medications 66423-5
610273 Methamphetamine 19554-5
20606 Creatinine, U 2161-8
604871 Alprazolam 94116-1
42323 Codeine 19411-8
42324 Codeine-6-beta-glucuronide 89310-7
604867 Alpha-Hydroxyalprazolam 19325-0
22312 Specific Gravity 5810-7
610274 Amphetamine 19343-3
610275 3,4-methylenedioxymethamphetamine (MDMA) 19568-5
23509 pH 2756-5
604891 Alpha-Hydroxyalprazolam Glucuronide 94115-3
42325 Morphine 19597-4
42326 Morphine-6-beta-glucuronide 89308-1
604872 Chlordiazepoxide 19385-4
23511 Oxidants 58714-7
610276 3,4-methylenedioxy-N-ethylamphetamine (MDEA) 59844-1
610277 3,4-methylenedioxyamphetamine (MDA) 19565-1
23510 Nitrites 32710-6
604889 Clobazam 94114-6
42327 6-monoacetylmorphine 19321-9
42328 Hydrocodone 19482-9
604890 N-Desmethylclobazam 94113-8
30914 Comment 48767-8
610278 Ephedrine 99108-3
610279 Pseudoephedrine 99109-1
604873 Clonazepam 19399-5
42329 Norhydrocodone 89304-0
42330 Dihydrocodeine 19446-4
604267 7-aminoclonazepam 94112-0
610280 Phentermine 19674-1
610281 Phencyclidine (PCP) 19659-2
604874 Diazepam 19443-1
42331 Hydromorphone 19486-0
42332 Hydromorphone-3-beta-glucuronide 89309-9
604880 Nordiazepam 19624-6
610282 Methylphenidate 19577-6
610283 Ritalinic acid 99110-9
604875 Flunitrazepam 19466-2
42333 Oxycodone 19642-8
42334 Noroxycodone 89303-2
604866 7-aminoflunitrazepam 94111-2
610284 Stimulant Interpretation 54247-2
604876 Flurazepam 19474-6
42335 Oxymorphone 19646-9
42336 Oxymorphone-3-beta-glucuronide 89301-6
604868 2-Hydroxy Ethyl Flurazepam 94110-4
604877 Lorazepam 19520-6
42337 Noroxymorphone 89302-4
42338 Fentanyl 59673-4
604878 Lorazepam Glucuronide 94109-6
604879 Midazolam 19585-9
42339 Norfentanyl 43199-9
42340 Meperidine 19532-1
604869 Alpha-Hydroxy Midazolam 94108-8
604881 Oxazepam 19638-6
42341 Normeperidine 27920-8
42342 Naloxone 42618-9
604882 Oxazepam Glucuronide 94107-0
604883 Prazepam 19678-2
42343 Naloxone-3-beta-glucuronide 89307-3
42344 Methadone 19550-3
604884 Temazepam 19698-0
604885 Temazepam Glucuronide 94106-2
42345 EDDP 93495-0
42346 Propoxyphene 19429-0
604886 Triazolam 19714-5
604870 Alpha-Hydroxy Triazolam 94105-4
42347 Norpropoxyphene 19632-9
42348 Tramadol 19710-3
604887 Zolpidem 94104-7
604888 Zolpidem Phenyl-4-Carboxylic acid 94103-9
42349 O-desmethyltramadol 86453-8
42350 Tapentadol 72485-6
604949 Benzodiazepine Interpretation 69050-3
42351 N-desmethyltapentadol 89306-5
42352 Tapentadol-beta-glucuronide 89300-8
42353 Buprenorphine 93494-3
42354 Norbuprenorphine 82371-6
42355 Norbuprenorphine glucuronide 89305-7
65059 Opioid Interpretation 69050-3