Test Code PLAIF Phospholipase A2 Receptor (PLA2R), Renal Biopsy
Ordering Guidance
This test will report as negative or positive for autoantibodies to phospholipase A2 receptor (PLA2R).
If additional interpretation/analysis is needed, request PATHC / Pathology Consultation along with this test and send the corresponding renal pathology light microscopy and immunofluorescence (IF) slides (or IF images on a CD), electron microscopy images (prints or CD), and the pathology report.
Shipping Instructions
1. Advise shipping unstained slides or tissue block specimens frozen in Styrofoam transportation coolers filled with dry ice to ensure specimens are received at required specimen stability temperature.
2. Attach the green pathology address label included in the kit to the outside of the transport container.
Necessary Information
A pathology/diagnostic report is required.
Specimen Required
Specimen Type: Kidney tissue
Preferred: Frozen unstained slides (unfixed)
Slides: 2 frozen tissue unstained positively charged glass slides (25- x 75- x 1-mm) per test ordered; sections 4-microns thick, centered on the slide, and submitted on dry ice.
Acceptable: Frozen Unfixed Tissue Block (OCT)
Container/Tube: Entire specimen
Collection Instructions: Send tissue embedded in OCT on dry ice.
Acceptable: Wet Tissue
Supplies: Renal Biopsy Kit (T231)
Container/Tube: Renal Biopsy Kit, Zeus/Michel's
Specimen Volume: Entire specimen
Collection Instructions: Collect specimens according to the instructions in Renal Biopsy Procedure for Handling Tissue for Light Microscopy, Immunofluorescent Histology, and Electron Microscopy.
Additional Information: If standard immunoglobulin and complement immunofluorescence have already been performed, submit the residual frozen tissue (must contain glomeruli) on dry ice.
Special Instructions
Method Name
Immunofluorescence
Reporting Name
PLA2R ImmunofluorescenceSpecimen Type
SpecialSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Special | Frozen (preferred) | ||
Ambient | |||
Refrigerated |
Reject Due To
Ambient slides | Reject |
Clinical Information
Membranous nephropathy is the most common cause of nephrotic syndrome in white adults. Eighty-five percent of membranous nephropathy cases are primary or idiopathic, and the other 15% are secondary. Phospholipase A2 receptor (PLA2R) is an antigen located on podocytes. The majority of cases of primary membranous nephropathy have circulating autoantibodies against PLA2R.
Interpretation
This test, when not accompanied by a pathology consultation request, will be reported as either positive or negative.
Cautions
No significant cautionary statements.
Method Description
Indirect immunofluorescence staining on sections of frozen tissue.(Unpublished Mayo method)
Day(s) Performed
Monday through Friday
Report Available
1 to 2 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
88346-primary IF
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
PLAIF | PLA2R Immunofluorescence | In Process |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
71225 | Interpretation | 59465-5 |
71226 | Participated in the Interpretation | No LOINC Needed |
71227 | Report electronically signed by | 19139-5 |
71228 | Addendum | 35265-8 |
71229 | Gross Description | 22634-0 |
71230 | Material Received | 81178-6 |
71617 | Disclaimer | 62364-5 |
71847 | Case Number | 80398-1 |