Test Code RVR Vancomycin-Resistant Enterococcus (VRE) Screen, Rapid
Performing Laboratory
Lima Memorial Health System Laboratory
Specimen Requirements
Container/Tube: Swab in transport tube
Collection Instructions:
Swab
1. Collect either a perirectal or rectal specimen using a culture transport swab.
2. Place swab in sterile culture transport tube.
3. Label tube with patient’s name (first and last), date of birth or medical record number, date and actual time of collection, and type of specimen.
4. Send specimen refrigerated. Specimen cannot be frozen. Maintain sterility and forward promptly.
Note: Specimen source is required.
Reference Values
Not Detected
Specimen Stability
Refrigerate: 5 Days
Day(s) Test Set Up
Monday through Sunday
Methodology
Polymerase Chain Reaction (PCR)
Test Classification and CPT Coding
87500