Test Code SWNDANA Culture/Smear, Surgical Wound, Anaerobic
Performing Laboratory
Lima Memorial Health System Laboratory
Specimen Requirements
Container/Tube: Sterile capped syringe
Collection Instructions:
1. Specimen should be obtained by using a needle and syringe from a source not normally colonized by anaerobes. Use pre-reduced anaerobic system (PRAS) for transport. (Swab is not desirable.)
2. Label container with patient’s name (first and last), date of birth or medical record number, date and actual time of collection, and type of specimen.
3. Forward promptly at ambient temperature only.
Note: Specimen source is required.
Reference Values
No growth or growth of pathogenic bacteria
Day(s) Test Set Up
Monday through Sunday
Methodology
Conventional Agar Technique
Includes a Gram stain and aerobic culture.
Test Classification and CPT Coding
87070 - Culture, aerobic
87076 - Culture, anaerobic
87205 - Gram stain