Test Code THSIF Thrombospondin Type 1 Domain Containing 7A (THSD7A), Immunofluorescence
Ordering Guidance
If additional interpretation/analysis is needed, request PATHC / Pathology Consultation along with this test and send the corresponding renal pathology light microscopy and immunofluorescence (IF) slides (or IF images on a CD), electron microscopy images (prints or CD), and the pathology report.
Necessary Information
A preliminary pathology report is required for testing to be performed. Send information with specimen. The laboratory will not reject testing if a reason for testing is not provided; however appropriate testing and interpretation may be compromised or delayed. If not provided, an appropriate indication for testing may be entered by Mayo Clinic Laboratories.
Specimen Required
Specimen Type: Kidney tissue
Preferred: 2 Unstained positively charged glass slide (25- x 75- x 1-mm) per test ordered; paraffin sections 3 to 4-microns thick
Acceptable: Formalin-fixed, paraffin-embedded (FFPE) kidney tissue block
Useful For
Diagnosis of thrombospondin type 1 domain-containing 7A (THSD7A)-associated membranous nephropathy
Method Name
Direct Immunofluorescence (DIF)
Reporting Name
THSD7A ImmunofluorescenceSpecimen Type
SpecialSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Special | Ambient (preferred) | ||
Frozen | |||
Refrigerated |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Thrombospondin type 1 domain-containing 7A (THSD7A) is a target antigen in membranous nephropathy (MN) and is detected in approximately 3% to 5% of non- phospholipase A2 receptor (PLA2R)-associated MN patients. Differentiating THSD7A-associated MN from PLA2R-associated MN is critical as approximately 20% of patients with THSD7A-associated MN have solid malignancy suggesting that THSD7A-associated MN is more likely to be secondary to malignancy than PLA2R-associated MN.
Interpretation
Staining is interpreted and reported as negative or positive.
Cautions
No significant cautionary statements
Method Description
Direct immunofluorescence staining on sections of formalin-fixed, paraffin-embedded kidney tissue.(Unpublished Mayo method)
Performing Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
88346-Primary IF
88350-If additional IF
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
THSIF | THSD7A Immunofluorescence | 101116-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
605245 | Interpretation | 50595-8 |
606383 | Participated in the Interpretation | No LOINC Needed |
606384 | Report electronically signed by | 19139-5 |
606385 | Addendum | 35265-8 |
606386 | Gross Description | 22634-0 |
606387 | Material Received | 22633-2 |
606388 | Disclaimer | 62364-5 |
606389 | Case Number | 80398-1 |
Specimen Minimum Volume
See Specimen Required
Day(s) Performed
Monday through Friday