Sign in →

Test Code VANCR Vancomycin, Random, Plasma or Serum

Performing Laboratory

Lima Memorial Health System Laboratory

Specimen Requirements

Preferred:
Container/Tube: Green cap-yellow ring Top (Lithium Heparin Gel) tube
Minimum Volume: 1.0 mL 
Collection Instructions: Plasma/serum for a peak level should be drawn 30 minutes to 2 hours after infusion. Centrifuge within 2 hours.
Also Acceptable:
Container/Tube: Plain, Red Top or Serum gel (SST-Gel) tube

Note:  1. If dosage and dosing information are provided, they will be included on report to enhance clinical interpretation.

Reference Values

Peak therapeutic range:  30.0-40.0 µg/mL
Trough therapeutic range:  5.0-10.0 µg/mL

Alarm values (automatic call-back):>40.0µg/mL

Specimen Stability

Ambient: 8 hours
Refrigerate: 48 hours
Frozen: aliquot for longer storage

Day(s) Test Set Up

Monday through Sunday

Methodology

Homogeneous Enzyme Immunoassay

Test Classification and CPT Coding

80202