Sign in →

Test Code VLTB Volatile Screen, Blood

Reporting Name

Volatile Scrn, B

Useful For

Detection and quantitation of acetone, methanol, isopropanol, and ethanol in whole blood

 

Quantification of the concentration of ethanol in blood that correlates with the degree of intoxication

 

Evaluation of toxicity to the measured volatile substances

 

This test is not intended for use in employment-related testing.

Testing Algorithm

This test includes analysis of methanol, ethanol, isopropanol, and acetone.

Method Name

Headspace Gas Chromatography Flame Ionization Detector (HSGC-FID)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Whole blood


Ordering Guidance


This test is not performed using chain of custody. For chain of custody testing, order VLTBX / Volatile Screen, Chain of Custody, Blood.



Additional Testing Requirements


If measurement of ethylene glycol is also needed, order ETGL / Ethylene Glycol, Serum.



Specimen Required


Container/Tube:

Preferred: Gray top (potassium oxalate/sodium fluoride)

Acceptable: Lavendar top (EDTA) or green top (sodium heparin)

Specimen Volume: 2 mL

Collection Instructions: Do not use alcohol to clean arm. Use alternatives such as Betadine to cleanse arm before collecting any specimen for volatile testing.


Specimen Minimum Volume

0.5 mL or amount to fill 1 tube

Specimen Stability Information

Specimen Type Temperature Time Special Container
Whole blood Refrigerated (preferred) 14 days
  Frozen  28 days
  Ambient  24 hours

Reject Due To

Gross hemolysis OK
Gross lipemia Reject
Gross icterus OK
 

Reference Values

Methanol:

Not detected (Positive results are quantitated.)

Toxic concentration: ≥10 mg/dL

 

Ethanol:

Not detected (Positive results are quantitated.)

Toxic concentration: ≥400 mg/dL

 

Isopropanol:

Not detected (Positive results are quantitated.)

Toxic concentration: ≥10 mg/dL

 

Acetone:

Not detected (Positive results are quantitated.)

Toxic concentration: ≥10 mg/dL

Day(s) Performed

Monday through Saturday

CPT Code Information

80320

G0480 (if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
VLTB Volatile Scrn, B 41266-8

 

Result ID Test Result Name Result LOINC Value
89190 Volatile Scrn, B 41266-8
30921 Methanol, B 9334-4
30922 Ethanol, B 5640-8
30923 Acetone, B 9425-0
30924 Isopropanol, B 5667-1
34377 Chain of Custody 77202-0

Clinical Information

Volatile substances in blood include ethanol, methanol, isopropanol, and acetone. Acetone is generally elevated in metabolic conditions such as diabetic ketoacidosis. Methanol and isopropanol are highly toxic and result from exogenous ingestion.

 

Ethanol is one of the most widely abused legal substances in the United States. It is the active agent in beer, wine, vodka, whiskey, rum, and other liquors. Ethanol acts on cerebral function as a depressant similar to general anesthetics. This depression causes most of the typical symptoms, such as impaired thought, clouded judgment, and changed behavior. As the level of alcohol increases, the degree of impairment progressively increases.

 

In most jurisdictions in the United States, the per se blood level for being under the influence of alcohol (ethanol) for purposes of driving a motor vehicle is 80 mg/dL (0.08%).

Interpretation

Methanol:

The presence of methanol indicates exposure that may result in intoxication, central nervous system (CNS) depression, and metabolic acidosis. Ingestion of methanol can be fatal if patients do not receive immediate medical treatment.

 

Ethanol:

The presence of ethanol indicates exposure that may result in intoxication, CNS depression, and metabolic acidosis.

 

Isopropanol:

The presence of isopropanol indicates exposure that may result in intoxication and CNS depression. Ingestion of isopropanol can be fatal if patients do not receive immediate medical treatment.

 

Acetone:

The presence of acetone may indicate exposure to acetone; it is also a metabolite of isopropanol and may be detected during ketoacidosis.

Cautions

This test does not detect ethylene glycol.

Method Description

Samples are analyzed and quantified by headspace gas chromatography with flame ionization detection.(Baselt RC. Disposition of Toxic Drugs and Chemicals in Man, 10th ed, Biomedical Publications; 2014:2211)

Report Available

1 to 2 days

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.